Concept System® 77 includes a high-quality flush door system, which meets the elevated requirements regarding thermal insulation, stability and security.
With regard to security, different door variants are specially designed and tested for burglar resistance, fire resistance, bullet proof and solutions for panic situations, meeting the most severe European standards.
This standard flush door range is available in all inward and outward opening types, realised with a wide range of door locks to meet every kind of locking demand.
Moreover, CS 77 flush doors are offered with different threshold solutions to perfectly match all comfort and aesthetic requirements. To ensure the tightness of the door, specially designed insulation strips are used to avoid possible bending of the element, caused by temperature difference between the in- and outside of the building.
Teknik Bilgiler
Properties | Performance | |||
Min. Visible width frame:inward opening | 68 mm | Air tightness max. test pressure | 7A (300 Pa) | |
Min. Visible width vent:inward opening | 76 mm | Water tightness | C2 (800 Pa) | |
Min. Visible width frame-vent:inward opening | 150 mm | Wind load resistance | C2 (800 Pa) | |
Min. Visible width frame: outward opening | 42 mm | Acoustic performance | Rw (C; Ctr) = 42 (-1; -4) dB | |
Min. Visible width frame-vent:outward opening | 102 mm | Güvenlik | ||
Min. Visible width T-profile | 76 mm | Burglar resistance | RC2/WK2 RC3/WK3 | |
Max. height vent | 3000 mm | Energy | ||
Max. width vent | 1400 mm | Thermal insulation (Uf) | 150mm: 2,1 | |
Max. weight element | 250 kg | |||
Overall system depth frame | 68 mm | |||
Overall system depth vent | 68 mm | |||
Rebate height | 25 mm | |||
Min. Glass thickness | 4 mm | |||
Max. Glass thickness | 52 mm | |||
Min. Glass thickness vent | 4 mm | |||
Max. Glass thickness vent | 52 mm |